Water Tight Technologies

  RUBBERALL® Family of Products
  RUBBERALL® Membrane Qualities
  Product Specifications & Safety Data Sheets
  Warranty
  Installation Manual
    General Information
    RUBBERALL® User Cautions And Warnings!
    RUBBERALL®Tools Needed
    RUBBERALL® Products Available
    Roof Surface Preparation
    Laying Out RUBBERALL® EPDM Membrane
    Pipe Penetrations
    Protrusion In The Roof
    Adhering Membrane With Solvent Based Bonding Adhesive
    Adhering Membrane With Water Based Bonding Adhesive
    Seaming Membrane Panels With Seam Tape
    Splicing And Seaming With Rubber To Rubber Adhesive
    Alternative Panel Layout And Seaming
    Perimeter Walls & Inside Corners
    Outside Corner Finish Detail
    Cover Strip
    Peel And Stick Pipe Boot
    Pipe Or Conduit Flashings Using Uncured Flashing With Tape
    Wall Termination
    T-Joints
    Field Seam Radical Bend
    Roof Edge Termination With Metal Drip Edge
    Terminating RUBBERALL® On Fascia
    RUBBERALL® Membrane To Shingle Transition
    One Piece Drain Sleeve
    Drains With Clamping Rings
    Pitch Pockets
    Protecting RUBBERALL® Membrane In High Foot Traffic Areas (Decks)
    Repair Of RUBBERALL® Membrane
    Application Review
    Frequently Asked Questions
    Glossary
    RUBBERALL® Roofing Membrane Material And Labor Limited Warranty
    Warranty Registration
  Installation Video Guide
 
see printer-friendly version

Drains With Clamping Rings

If the existing drain has a clamping ring assembly, remove the strainer, clamping ring bolts and clamping ring. Clean the drain bowl, clamping ring flange and clamping ring. Do not allow debris to clog drain pipe.

Install the field membrane over the drain. To determine where to cut the hole, place the drain clamping ring over the membrane onto the clamping ring flange. Allow the membrane to extend one inch (1") past the clamping ring.

After the membrane has been cut, lift the membrane and apply several heavy beads of Water Cut-Off Mastic to the clamping ring flange. It is recommended to use a minimum of one-half (1/2) tube per drain.

Align the clamping ring over the membrane and punch holes where necessary to install the clamping ring bolts. Do not cut the membrane back to the bolts. Secure the clamping ring and install the strainer.

Figure 30

 
 
Home About RUBBERALL Roofing Products Water Garden Products Contact Us About BRITE-N-EZ BRITE-N-EZ Roofing Products Roof Coatings Site Map